SDC 2002
4.2. Home Menu
4-14
Operating Instructions - Rev. 1 / 6.2003
Function Buttons, Controls & Displays
1. TK Remote
Tk Remote
The Tk Remote toggle switch delegates the selected control functions of the
film scanner either to the GCP (Rem1) or to the local control panel.
2. Master
Control
Master control
The “Master control” button sets all remoteable functions like filmdeck, video
& audio amps, the scanning system and monitoring selection to Remote1 or
Local control.
3. This Panel
For connecting the GCP to Remote 1 - 3
If a film scanner has to be controlled from several remote panels (FCP and GCP),
consider the following:
In order to avoid problems with parallel operation, the default setting of the GCP
should always be REMOTE 2. When changing the remote address of the GCP, the
film scanner has subsequently to be restarted.
4.1 Filmdeck Selects remote interface for the film deck.
For controlling the filmdeck, optionally via the own (Local) control panel or an ex-
ternal control panel.
Remote 1 to 3 are iMCS (Cheapernet) control connections.
Rem 1 is provided for the Graphical Control Panel and Rem 2 and 3 for external
color corrections.
Rem ote 4, 5 are RS422 interfaces for connecting an editor or a filmdeck control
panel. Only for future use.
Parallel is a parallel interface for connecting a control panel with reduced filmdeck
functions.