SDC 2002
3. Operational Preparations
3-42
Operating Instructions - Rev. 1 / 6.2003
12
Run film
for adjusting
the intensity of film illumination
Search for a scene with low film density (bright
lights, clouds or similar) and adjust the inten-
sity of film illumination in such a way that the
brightest one of the RGB video signals
reaches a level of 100 % (oscilloscope).
”CCD Output Level Display:
During adjustment watch the CCD Output
Level Display!
Make sure that this level is around 85%.
Or during Play:
Pressing the “Flash button” sets film illumina-
tion intensity at once to maximum CCD out-
put level.
If 100 % video level is not reached, switch
video basic gain to + 6 dB (see section 3.10.4.)
and adjust the film illumination intensity again.
Attention!
Exceeding 22A lamp current may shorten
the life span of the projection Xenon
lamp.
13