4.9 Sprecial Menu SDC 2002
4-188
Operating Instructions - Rev. 1 / 6.2003
during measurement after the servo of the SDC 2000/2001 is absolutely stable (60
frames after servo has locked).
To ensure that the first frames, following the leader, are corrected properly, the rul-
ers have to be adjusted with the beginning of the film and not with the leader.
To start the correct film transfer, rewind into the leader section and start the transfer
mode. This minimizes the constant offset which is contained in correction values.
Please notice, if several pieces of film shall be scanned sequentially and overlaid
afterwards, that setting the reference shall be done only once with the first film.
Otherwise, there are displacements in the overlays because of the different offsets
in the scanning sessions.
All user parameters are saved on harddisk and restored at program initialization.
Perforation hole illumination adjustment
If white dots or white vertical stripes , caused by camera saturation, appear in the
displayed hole image, reduce the illumination level until dots and stripes disappear.
Perform adjustment by sliding on the touchscreen or use the digipot.
If vertical stripes of various colors appear in the VGA display, the illumination win-
dow has to be cleaned. See chapter “Maintenance” in the separate Steadiscan
manual.